====== Apple XRaid ====== [[http://manuals.info.apple.com/en/XserveRAID_UserGuide.PDF]] [[http://manuals.info.apple.com/en/Xserve_RAID_Users_Guide.pdf]] [[http://manuals.info.apple.com/en/RAIDAdmin1.2_121406.pdf]] ===== log of events ===== *05/30/2007 Drive 13 offline. Action: Re-seated drive; will replace on 2nd error. * 09/06/2007 Drive 3 offline. Action: Re-seated drive; will replace on 2nd error. * 11/20/2007 Self-Monitoring, Analysis and Reporting Technology (SMART) drive error on drive 1 (indicating possible future failure.) Action: Re-seated drive; will replace on 2nd error. * 12/04/2007 /home/facultystaff partition journal abort causing it to be automatically remounted read only. Action: reboot server and run fsck to restore the partition. * 12/11/2007 /home/grad partition journal abort causing it to be automatically remounted read only. Action: reboot server and run fsck to restore the partition. Action: reboot server and run fsck to restore the partition and replaced disk 1 with new drive though no other indication showed it had errors. On reboot, all partitions ran fsck as it had been 187 days since last check. * 12/13/2007 /home/grad partition journal abort causing it to be automatically remounted read only. Action: reboot server and run fsck to restore the partition. Took system back down including disk array and reseated all drives cleaning dust out of disk array box. * 12/14/2007 Drive 3 off-line. Action: Replaced with original disk 1 from 12/11/2007 swap. This drive probably needs to be replaced with a new one since is gave 1 SMART error. * 6/23/2011 * 8/10/2011 Disk6 Reported an ATA error...this is a failure in the communications from the RAID controller to the Drive. [[http://publib.boulder.ibm.com/infocenter/dsichelp/ds8000ic/index.jsp?topic=/com.ibm.storage.ssic.help.doc/f2c_intllndynsan_2hsag7.html|rescan devices]]